PreciS™-A HbA1c Analysis System

With PreciS™-A HbA1c analysis system, healthcare professionals can be assured that they are getting accurate, reliable and cost-effective results to monitor diabetes patients and give related therapeutic regimen.

PreciS™-A HbA1c Analysis System

With PreciS™-A HbA1c analysis system, healthcare professionals can be assured that they are getting accurate, reliable and cost-effective results to monitor diabetes patients and give related therapeutic regimen.

Diabetes Mellitus is a metabolic disease due to either pancreatic cells not producing sufficient insulin or the body not reacting to insulin for glucose management. Failure to manage diabetes can result in disease complications such as retinopathy, nephropathy, ischaemic heart disease, foot ulcers and stroke. This can lead to reduced quality of life, increased financial burden and reduced life expectancy.

Management of diabetic patients includes monitoring of blood glucose and glycated A1c (or HbA1c) and introducing required interventions to prevent unnecessary hyper or hypoglycemia episodes. The HbA1c test involves measurement of HbA1c in blood samples and where the results indicate the level of blood glucose level in the past 2 to 3 months.

PreciS™-A HbA1c Analysis System utilizes a Boronate Affinity Chromatography method to quantitatively measure the level of HbA1c in whole blood. A solid phase separation matrix is implemented as a membrane that has been chemically modified to contain both negatively charged groups and boronate groups. When the pH of the buffer flowing through the matrix is acidic, positively charged HbA1c and non-glycohemoglobin bind to the negatively charged groups. When the pH is basic, the hemoglobin loses its charge and is released from the ionic binding. At basic pH, boronate binds not only cis-diols but also the glucose of glycohemoglobin in the matrix. The analyzer uses an optical reflectance measurement technique to quantify the hemoglobin bound in the matrix under each condition. The ratio of the glycohemoglobin to the total hemoglobin is calculated and reported as %NGSP or IFCC mmol/mol.

Excellent Design

  • Stylish handheld size
  • 3 easy steps with voice prompt to facilitate the whole process

Reliable Results

  • NGSP & IFCC certification
  • Boronate Affinity Chromatography Technology, no interference from HbF, HbE and other variable and unstable Hb

Key benefits of PreciS™-A HbA1c Analysis System

  • Portable and easy to handle – palm-sized and lightweight analyzer
  • Sample is easy to obtain from patient – uses capillary blood samples (~3 μL).
  • Rapid results (within 6 minutes) enable users to facilitate immediate intervention where required
  • Test strips have a long shelf life and are kept at room temperature
  • Voice prompt to remind users of required steps

Analyzer and Test Kit Specifications

Parameter Specification
Principle
Boronate affinity chromatography
Analyte
HbA1c
Sample Type
Capillary Blood
Sample Volume
Around 3 to 5 μL
Metric
NGSP (%)/IFCC (mmol/mol)/eAG (mg/dL or mmol/L)
Test Range
4.0% - 14.0%
Strips and Reagents Storage Condition
4°C - 30°C
Analyzer Size
122.6mm x 61.0mm x 24.5mm
Analyzer Weight
112 g (without battery)
Analyzer Power Supply
AAA battery x 4
Analyzer Warranty
5 years (date of purchase)
Working Condition
Temperature: 10°C - 40°C; Humidity: 30% - 75%
Printer
Supported by external printer (purchase separately)
Data Storage
1000

Order Information

Product Name Product Code
PreciS™-A HbA1c Analyzer
SGM00100
PreciS™-A HbA1c Test Kit, 25 Tests (For Professional Use Only)
SG001000H
PreciS™-A HbA1c Test Kit, 12 Tests (For Professional Use Only)
SG001000E
PreciS™-A HbA1c Test Kit, 2 Tests (For Self Testing)
SG001000B